Specification | M12 |
Mounting | Non-Flushed |
Sensing distance | 4mm±10% |
Set distance | 0~3.2mm |
Hysteresis error | 3~20%(sensing distance) |
Repeat accuracy | <5%(sensing distance) |
Output mode | N:NPN, NA:NPN-NO, NB:NPN-NC, P:PNP, PA:PNP-NO, PB:PNP-NC |
Response frequency | 50Hz |
Standard target | 12X12X1t |
Temperature effect | -25℃~70℃,within±10%(+23℃ sensing distance) |
Power supply | DC12-24V impulse(p-p)<10%(DC10-30V) |
Current consumption | <20mA |
Voltage effect | <3% |
Residual voltage | <2.5V(load current 200mA&cable 2m) |
Load current | <200mA |
Circuit protection | Reverse connection protection,short circuit protection,electrical surge absorption |
Indicator light | Red LED |
Leakage current | <100uA |
Connection | Cable 2m |
Ambient temperature | Work&store:-25℃~70℃ |
Ambient humidity | Work&store:35% ~ 95% |
Anti-vibration | 10~55Hz,1.5mm double amplitude for 2H each in,X,Yand Z directions |
Withstanding voltage | 1000VAC,50/60Hz for 1min between current-carrying parts and case |
Insulation resistance | >50MΩ min.(at 500VDC)between current-carrying parts and case |
Protection degree | IEC IP65 |
Housing | PA66 |