Specification | M30 |
Mounting | Flushed |
Sensing distance | 10mm±10% |
Set distance | 2.5~15mm |
Hysteresis error | 3~15% of sensing distance |
Repeat accuracy | <3% of sensing distance |
Output mode | NPN/PNP |
Response frequency | 50Hz |
Temperature effect | -25℃~70℃, sensing distance within ±20% at +23℃
|
Power supply | DC 12-24V pulse(p-p)<10%(DC 10-30V) |
Current consumption | <10mA |
Voltage effect | <3% |
Residual voltage | <2.5V (load current 200mA&cable 2m) |
Load current | <200mA |
Circuit protection | Reverse polarity connection protection, short circuit protection, electrical surge absorption |
Indicator light | Output: organge LED; Power: Green LED |
Leakage current | <100uA |
Connection | Cable 2m |
Ambient temperature | Work&store: -25℃~70℃ |
Ambient humidity | Work&store: 35% ~ 95%RH |
Anti-vibration | 10~55Hz, 1.5mm double amplitude for 2H each in,X,Yand Z directions |
Withstanding voltage | 750V AC, 50/60Hz for 1min between current-carrying parts and case |
Insulation resistance | >20MΩ min at 500V DC between current-carrying parts and case |
Protection degree | IEC IP67 |
Housing | Nickel-copper alloy |