Specification | 30×30.5×53 |
Mounting Flushed | Non-Flushed |
Sensing distance | 15mm±10% |
Set distance | 0~12mm |
Hysteresis error | 1~15% of sensing distance |
Repeat accuracy | Less than 3% of sensing distance |
Output Type | NO |
Response frequency | 0.3KHz |
Standard target | 45X45X1t(Q235A) |
Temperature effect | Between -25℃~+70℃, less than 10% of sensing distance at +23℃ |
Power supply | DC 12-24V pulse (p-p)<10%(DC 10-30V) |
Current consumption | <10mA |
Voltage effect | <3% |
Residual voltage | Less than 2.5V( load current at 200mA & cable 2m) |
Load current | <200mA |
Circuit protection | Reverse polarity connection protection, short circuit protection,electrical surge absorption |
Indicator light | Red LED |
Leakage current | <100uA |
Connection | Cable-2m |
Ambient temperature | Work&store:-25℃~70℃ |
Ambient humidity | Work&store:35~95% RH |
Anti-vibration | 10~55Hz, up-down amplitude 1.5mm,X,Y,Z(2H) |
Withstanding voltage | 1000V AC, 50/60Hz 1min between current-carrying parts and case |
Insulation resistance | >50MΩ(DC500V megger) between current-carrying parts and case |
Protection degree | IEC IP67 |
Housing | PBT+ABS |