Specification | 8×6×25 |
Mounting | Non-Flushed |
Sensing distance | 2.5mm±10% |
Set distance | 0~2mm |
Hysteresis error | 1~15% of sensing distance |
Repeat accuracy | Less than 3% of sensing distance |
Output mode | NPN/PNP |
Output state | NO/NC |
Response frequency | 1KHz |
Standard target | 8X8X1t(Q235A) |
Temperature effect | -25℃~70℃,within±10%(+25℃ sensing distance) |
Power supply | DC12-24V impulse(p-p)<10%(DC10-30V) |
Current consumption | <10mA |
Voltage effect | <3% |
Residual voltage | <1.5V(load current 100mA&cable 2m) |
Load current | <100mA |
Circuit protection | Reverse Connection protection,short circuit protection,electrical surge absorption |
Indicator light | Red LED |
Leakage current | <100uA |
Connection | Cable(2m)or Connection terminal |
Ambient temperature | Work&store:-25℃~70℃ |
Ambient humidity | Work&store:35~95% |
Anti-vibration | 10~55Hz,Amplitude 1.5mm,X,Y,Z(2H) |
Withstanding voltage | 500V AC,50/60Hz 1min between current-carrying parts and case |
Insulation resistance | >50MΩ(DC500V megger)between current-carrying parts and case |
Protection degree | IEC IP67 |
Housing | PC |