| Pressure range | min 0~350KPa,max 0~70MPa |
| Pressure unit | K:KPa; M:MPa; B:bar; P:PSi |
| Output | B5:4~20mV |
| Accuracy | 6:±1.0% |
| Zero tolerance | <±1% of FS |
| Full scale difference | <±1% of FS |
| Supply voltage | 10~30 V DC |
| Output resistance | >10k Ohms |
| Supply current | <24mA |
| Frequency | (-3dB):DC to 250Hz |
| Output load | 0~1000 ohms @10-30V DC |
| Reverse polarity protection | YES |
| Long-term stability | ±0.25% FS/year |
| Contact medium | 17-4PH (316L optional) |
| Pressure cycling | >0.1billion times full pressure cycling |
| Overload pressure | 2 times rated pressure |
| Burst pressure | 5 times rated pressure (max 150Mpa) |
| Comprehensive error | ±0.5% FS (within compensated temperature) |
| Ambient temperature | Temperature range -40℃~125℃; Compensated temperature range 0~70℃,-25℃~85℃ |
| Insulation resistance | >100M/250V DC |
| Anti-vibration | ±20g |
| Anti-impact | 50g,11msec,1/2 sine wave |
| Anti-EMI | EN 50081-2 EN 50082-2(10V/M,26-1000MHz) EN 61326 |
| Mounting | M:M20X1.5 |
| Connection | C1:1m cable, P0:packard connector, H0:Hirschman connector, M0:M12X1 connector, XX:others |