| Specification | M30 | 
| Mounting | Flushed | 
| Sensing distance | 10mm±10% | 
| Set distance | 0~8mm | 
| Hysteresis error | 1~20% of sensing distance | 
| Repeat accuracy | <3% of sensing distance | 
| Output mode | NPN/PNP - NO 
 | 
| Response frequency | 500Hz | 
| Standard target | 30X30X1t(Q235A) | 
| Temperature effect | -25℃~120℃, sensing distance within ±10% at +23°C | 
| Power supply | DC 12-24V pulse(p-p)<10%(DC 10-30V) | 
| Current consumption | <15mA | 
| Voltage effect | <3% | 
| Residual voltage | <2.5V(load current 200mA&cable 2m) | 
| Load current | <200mA | 
| Circuit protection | Reverse polarity connection protection,short circuit protection,electrical surge absorption | 
| Indicator light | --------- | 
| Leakage current | <100uA | 
| Connection | Cable-2m | 
| Ambient temperature | Work&store:-25℃~70℃ | 
| Ambient humidity | Work&store:35~95% RH | 
| Anti-vibration | 10~55Hz, up-down amplitude 1.5mm, X,Y,Z(2H) | 
| Withstanding voltage | 1000V AC,50/60Hz 1min between current-carrying parts and case | 
| Insulation resistance | >50MΩ(DC 500V megger)between current-carrying parts and case | 
| Protection degree | IEC IP67 | 
| Housing material | Nickey-copper alloy | 
| Sensing face | PTFE |