| Specification | M18 |
| Mounting | Flushed |
| Sensing distance | 5mm±10% |
| Set distance | 0~4mm |
| Hysteresis error | 1~20% of sensing distance |
| Repeat accuracy | <3% of sensing distance |
| Output mode | NPN/PNP - NO
|
| Response frequency | 800Hz |
| Standard target | 18X18X1t(Q235A) |
| Temperature effect | -25℃~120℃, sensing distance within ±10% at +23°C |
| Power supply | DC 12-24V pulse(p-p)<10%(DC 10-30V) |
| Current consumption | <15mA |
| Voltage effect | <3% |
| Residual voltage | <2.5V(load current 200mA&cable 2m) |
| Load current | <200mA |
| Circuit protection | Reverse polarity connection protection,short circuit protection,electrical surge absorption |
| Indicator light | --------- |
| Leakage current | <100uA |
| Connection | Cable-2m |
| Ambient temperature | Work&store:-25℃~70℃ |
| Ambient humidity | Work&store:35~95% RH |
| Anti-vibration | 10~55Hz, up-down amplitude 1.5mm, X,Y,Z(2H) |
| Withstanding voltage | 1000V AC,50/60Hz 1min between current-carrying parts and case |
| Insulation resistance | >50MΩ(DC 500V megger)between current-carrying parts and case |
| Protection degree | IEC IP67 |
| Housing material | Nickey-copper alloy |
| Sensing face | PTFE |