Sensing mode | U type through beam reflection |
Number of optical axis | 1 optical axis |
Standard target | Ф5mm |
Output mode | Dark ON |
Sensitivity adjustment | Fixed |
Slot width | 30mm |
Repeatability | Perpendicular to the test axis: under 0.5mm |
Power supply | DC 10-30V |
Current consumption | 25mA |
Response Time | 1ms |
Output control |
NPN open-collector output Maximum inflow current: 100mA Impressed voltage: below 30V DC (between output and 0V) Residual voltage: below 2.5V (current is 100mA) |
Circuit protection | Power reverse connection protection, output short circuit protection, over-current protection circuit, mutual interference prevention function |
Indicator light | Output: red ;Stable: green |
Light source | Infrared light(850nm) |
Insulation resistance | More than 50MΩ(DC500V megger) |
Automatic anti-interference function | Equipped |
Withstand voltage | 1,500V AC, 50/60Hz 1min between current-carrying parts and case |
Anti-vibration | 10 ~ 55 Hz double amplitude 1.5mm x, y, z direction 2H |
Anti-impact | 500m/s² X, Y, Z 3 times |
Ambient illumination | Sunlight: 10000lx incandescent lamp: 5000lx (illuminance of light receiving surface) |
Ambient temperature | Work:-25℃~+55℃, Store: -40℃~70℃, dewde forbidden&iced forbidden
|
Ambient humidity | Work:-35%~+85%RH, Store: 35~95%RH, dewde forbidden |
Protection degree | IEC IP65 |
Connection | Cable 2m PVC |
Housing material | Housing: PBT+ABS |