Model | S2000 |
Control mode | V/F control, Open loop vector control |
Maximum frequency | Vector control: 0 ~ 320hz V/F control: 0 ~ 3200hz |
Carrier frequency | 1kHz ~ 16KHz, carrier frequency can be adjusted automatically according to load characteristics |
Input frequency resolution | Digital setting: 0.01Hz analog setting: maximum frequency x 0.025% |
Starting torque | Type G: 0.5hz/150% (without PG) Type P: 0.5hz/100% |
Speed range | 0.111111111 |
Steady speed accuracy | ±0.5% |
Overload capacity | Type G: 150% rated current 60s; 180% rated current 3S; Type P: 120% rated current 60s; 150% rated current 3S |
Torque increase | Automatic torque increase; manual torque increase 0.1% ~ 30% |
V/F curve | Three ways: straight line, multipoint, N-power V / F curve (1.2 power, 1.4 power, 1.6 power , 1.8 power, 2 power ) |
V/F separation | Two ways: total separation and semi separation |
Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time, acceleration and deceleration time range 0 ~ 6500s |
DC braking | DC braking frequency: 0Hz ~ maximum frequency; braking time: 0s ~ 100s; braking action current: 0% ~ 100% |
Inching control | Inching frequency range: 0 Hz ~ 50 Hz. Inching acceleration and deceleration time: 0s ~ 6500s |
Simple PLC, multi speed operation | Through the built-in PLC or control terminal to achieve up to 16 section speed operation |
Built in PID | The closed-loop control system of process control can be easily realized |
Automatic voltage regulation | When the grid voltage changes, it can automatically keep the output voltage constant |
Over voltage and over current stall control | Automatically limit the current and voltage during operation to prevent frequent over-current and over-voltage trip |
Fast current limiting function | Minimize the over-current fault and protect the normal operation of frequency converter |
Torque limitation and control | The 'excavator' feature automatically limits the torque during operation to prevent frequent over-current trips |
Excellent performance | Asynchronous motor control based on high performance current vector control technology |
Still working with instant stop | In case of instantaneous power failure, the load feedback energy compensates for the decrease of voltage and keeps the inverter running for a short time |
Fast current limiting | Avoid frequent over-current fault of frequency converter |
Timing control | Timing control function: set the time range of 0min ~ 6500min |
Communication mode support | RS-485 |
Run command channel | Keyboard setting, control terminal setting and serial communication port setting can be switched in various ways |
Frequency source | 10 kinds of frequency sources: digital given, analog voltage given, analog current given, pulse given, serial port given. It can be switched in a variety of ways |
Auxiliary frequency source | 10 kinds of auxiliary frequency sources. It can flexibly realize auxiliary frequency trimming/ frequency synthesis |
Input terminal | Standard: six digital input terminals, one of which supports high-speed pulse input of up to 100kHz; two analog input terminals, one only supports 0 ~ 10V voltage input; one supports 0 ~ 10V voltage input or 4 ~ 20mA current input |
Output terminal | One digital output terminal, one relay output terminal and one analog output terminal, supporting 0 ~ 20mA current output or 0 ~ 10V voltage output |
LED dispay | Display parameters |
Key locking and function selection | Complete the partial or total locking of keys, and define the action range of some keys to prevent misoperation |
Protection function | Short circuit detection, output open phase protection, over-current protection, over-voltage protection, under voltage protection, overheat protection, overload protection, etc |
Place | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, water vapor, dripping or salt, etc |
Altitude | Lower than 1000m (need to downshift when higher than 1000m) |
Ambient temperature | -10℃~+40℃ (Downshift when the ambient temperature between 40 ℃ ~ 50 ℃ )
|
Ambient humidity | Less than 95% RH, no condensation |
Vibration | lower than 5.9m/S2(0.6g) |
Storage temperature | -20℃~+60℃ |