| Working Voltage | 24VDC±20% |
| Measuring Range | 50~1500mm |
| Maximum Detectable Speed | 10m/s |
| Output Signal | V:Voltage0-10V A: Current 4~20mA |
| Operating Current | Measuring length <1500:140 mA Measuring length ≥1500:180 mA |
| Number of Magnets | 1 |
| Nonlinearity Error | ±40um<1000 mm ±60um≥1000.…1500mm ±100um>1500mm |
| Repeatability Error | ≤±10μm |
| Resolution | 16Bit D/A |
| Short-circuit Protection | To ground |
| Reverse Polarity Protection | Yes |
| Temperature Influence | <10μm/℃(≤500 mm) |
| Storage Temperature | -30℃~+80℃ |
| Operating Temperature | -25℃~+80℃ |
| EN 55016-2-3,Radiation | Industrial and residential areas |
| EN 60068-2-27, Shock | 150g |
| EN 60068-2-6,Vibration | 10g,10~2000 Hz |
| EN 61000-4-2,ESD | Severity Level 3 |
| EN 61000-4-3,RFI | Severity Level 3 |
| EN 61000-4-4,Burst | Severity Level 3 |
| EN 61000-4-5, Surge | Severity Level 3 |
| EN 61000-4-6,High-frequency Field | Severity Level 3 |
| EN 61000-4-8,Magnetic Field | Severity Level 4 |
| Housing Material & Surface Protection | Aluminum (Anodized) |
| Wiring Method | Connector 1x4Pin/M12 |
| Protection Grade | IP65 |