| Specification | M8 |
| Mounting | Flushed |
| Sensing distance | 1.5mm±10% |
| Set distance | 0~1.2mm |
| Response frequency | 2KHz |
| Standard target | 8*8*1t(Q235A) |
| Output type | N: NPN, NA: NPN-NO, NB: NPN-NC, P:PNP, PA: PNP-NO, PB: PNP-NC |
| Hysteresis error | 1%~15% of sensing distance |
| Repeat accuracy | Less than 3% of sensing distance |
| Power supply | DC 12~24V pulse (p-p) less than 10% (DC 10-30V) |
| Current consumption | <10mA |
| Leakage current | < 100uA |
| Residual voltage | Less than 2V( load current at 100mA &cable 2m) |
| Load current | <100mA |
| Circuit protection | Reverse polarity connection protection, short circuit protection, Electrical surge absorption |
| Indicat light | Yellow LED |
| Connection | Standard cable 2m |
| Ambient temperature | Work and store:-25℃~+70℃ |
| Temperature effect | Between -25℃~+70℃, less than 10% of sensing distance at +23℃ |
| Ambient humidity | Work and store:35~95% RH |
| Voltage effect | <3% |
| Anti-vibration | 10 to 50 Hz with 1.5 mm double amplitude for 2 hrs each in X, Y, and Z directions |
| Withstanding voltage | 500V AC,50/60Hz 1min |
| Insulation resistance | >20MΩ(DC 500V) |
| Protection degree | IEC IP67 |
| Housing | Stainless steel |