| Specification | 7X30X50 |
| Mounting | Non-Flushed |
| Sensing distance | 8mm±10% |
| Set distance | 0~6.4mm |
| Hysteresis error | 3~15% at sensing distance |
| Repeat accuracy | <5% at sensing distance |
| Output mode | NPN/PNP |
| Output state | NC |
| Response frequency | 100Hz |
| Standard sensing object | Grounded metal plate: 50X50X1t |
| Temperature effect | -25℃~70℃, sensing distance within ±20% at +23℃
|
| Power supply | DC 12-24V pulse(p-p)<10%(DC 10-30V) |
| Current consumption | <20mA |
| Voltage effect | <3% |
| Residual voltage | <2.5V(load current 200mA&cable 2m) |
| Load current | <200mA |
| Circuit protection | Reverse polarity connection protection, surge absorption |
| Indicator light | Red LED |
| Connection | Pre-wired models (Standard cable length:2m) |
| Ambient temperature | Work&store:-10℃~55℃ |
| Ambient humidity | Work&store:35% to 95%RH |
| Anti-vibration | 10~55Hz, 1.5mm double amplitude for 2H each in,X,Yand Z directions |
| Withstanding voltage | 1000VAC, 50/60Hz for 1min between current-carrying parts and case |
| Insulation resistance | >50MΩ min at (500VDC) between current-carrying parts and case |
| Protection degree | IEC IP67 |
| Housing | PBT |