| Specification | 11×8×33 |
| Mounting | Flushed |
| Sensing distance | 4mm±10% |
| Set distance | 0~3.2mm |
| Output mode | NPN/PNP |
| Output state | NC |
| Hysteresis error | 1~15% of sensing distance |
| Repeat accuracy | Less than 5% of sensing distance |
| Response frequency | 0.5KHz |
| Standard target | 12X12X1t(Q235A) |
| Temperature effect | -25℃~70℃,sensing distance within±10% at +25℃
|
| Power supply | DC12-24V pulse(p-p)<10%(DC10-30V) |
| Current consumption | <10mA |
| Voltage effect | <3% |
| Residual voltage | <1.5V(load current 100mA&cable 2m) |
| Load current | <100mA |
| Circuit protection | Reverse polarity connection protection,short circuit protection,electrical surge absorption |
| Indicator light | Red LED |
| Leakage current | <100uA |
| Connection | Cable-2m or Connection terminal |
| Ambient temperature | Work&store: -25℃~70℃ |
| Ambient humidity | Work&store: 35~95%RH |
| Anti-vibration | 10~55Hz, up-down amplitude 1.5mm,X,Y,Z(2H) |
| Withstanding voltage | 1000V AC, 50/60Hz 1min between current-carrying parts and case |
| Insulation resistance | >50MΩ(DC 500V megger) between current-carrying parts and case |
| Protection degree | IEC IP67 |
| Housing | PC |