| Specification | 5.5×5.5×19 |
| Mounting | Flushed |
| Sensing distance | 1.5mm±10% |
| Set distance | 0~1.2mm |
| Hysteresis error | 1~15% of sensing distance |
| Repeat accuracy | Less than 3% of sensing distance |
| Output mode | NPN/PNP |
| Output state | NC |
| Response frequency | 1.5KHz |
| Standard target | 5X5X1t(Q235A steel plate) |
| Temperature effect | -25℃~70℃, sensing distance within±10% at +25℃
|
| Power supply | DC 12-24V pulse(p-p)<10%(DC 10-30V) |
| Current consumption | <10mA |
| Voltage effect | <3% |
| Residual voltage | <1.5V(load current 100mA&cable 2m) |
| Load current | <100mA |
| Circuit protection | Reverse polarity connection protection, short circuit protection, electrical surge absorption |
| Indicator light | Red LED |
| Leakage current | <100uA |
| Connection | Cable(2m) or Connection terminal |
| Ambient temperature | Work&store:-25℃~70℃ |
| Ambient humidity | Work&store:35~95%RH |
| Anti-vibration | 10~55Hz, up-down amplitude 1.5mm,X,Y,Z(2H) |
| Withstanding voltage | 500V AC, 50/60Hz 1min between current-carrying parts and case |
| Insulation resistance | >50MΩ(DC 500V megger) between current-carrying parts and case |
| Protection degree | IEC IP67 |
| Housing material | PC |