Specification | 11×8×33 |
Mounting | Flushed |
Sensing distance | 4mm±10% |
Set distance | 0~3.2mm |
Output mode | NPN/PNP |
Output state | NO |
Hysteresis error | 1~15% of sensing distance |
Repeat accuracy | Less than 5% of sensing distance |
Response frequency | 0.5KHz |
Standard target | 12X12X1t(Q235A) |
Temperature effect | -25℃~70℃,sensing distance within±10% at +25℃
|
Power supply | DC12-24V pulse(p-p)<10%(DC10-30V) |
Current consumption | <10mA |
Voltage effect | <3% |
Residual voltage | <1.5V(load current 100mA&cable 2m) |
Load current | <100mA |
Circuit protection | Reverse polarity connection protection,short circuit protection,electrical surge absorption |
Indicator light | Red LED |
Leakage current | <100uA |
Connection | Cable-2m or Connection terminal |
Ambient temperature | Work&store: -25℃~70℃ |
Ambient humidity | Work&store: 35~95%RH |
Anti-vibration | 10~55Hz, up-down amplitude 1.5mm,X,Y,Z(2H) |
Withstanding voltage | 1000V AC, 50/60Hz 1min between current-carrying parts and case |
Insulation resistance | >50MΩ(DC 500V megger) between current-carrying parts and case |
Protection degree | IEC IP67 |
Housing | PC |